209
APPENDICES
A
Appendix 5 Dedicated Instruction
Appendix 5.1 Instruction list
Appendix 5 Dedicated Instruction
This chapter describes the dedicated instructions that can be used in A/D converter module.
Appendix 5.1 Instruction list
The following shows the dedicated instructions that can be used in the A/D converter module.
Instruction Description
G(P).OFFGAN
• The operation mode is changed to the offset/gain setting mode.
• The operation mode is changed to the normal mode.
G(P).OGLOAD The offset/gain set value in the user range setting is read out to the CPU module.
G(P).OGSTOR
The offset/gain set value in the user range setting stored in the CPU module is restored to the
A/D converter module.