173
APPENDICES
A
Appendix 1 Details of I/O Signals
Appendix 1.2 Output signal
(3) Channel change request (YB)
Turn Channel change request (YB) OFF ON OFF to change a channel to perform the offset/gain setting.
For the timing of turning the signal OFF ON OFF, refer to the following.
Channel change completed flag (XB) ( Page 167, Appendix 1.1)
(4) Maximum value/minimum value reset request (YD)
Turn Maximum value/minimum value reset request (YD) OFF ON OFF to clear the maximum or minimum
values stored in CH Maximum value (Un\G30, Un\G32, Un\G34, Un\G36) and CH Minimum value (Un\G31,
Un\G33, Un\G35, Un\G37).
For the timing of turning the signal OFF ON OFF, refer to the following.
Maximum value/minimum value reset completed flag (XD) ( Page 167, Appendix 1.1)
(5) Error clear request (YF)
To clear Error flag (XF), Input signal error detection signal (XC), and Latest error code (Un\G19), turn Error clear
request (YF) OFF ON OFF.
For the timing of turning the signal OFF ON OFF, refer to the following.
Input signal error detection signal (XC) ( Page 167, Appendix 1.1)
Error flag (XF) ( Page 167, Appendix 1.1)

Table of Contents

Other manuals for Mitsubishi L Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi L Series and is the answer not in the manual?

Mitsubishi L Series Specifications

General IconGeneral
BrandMitsubishi
ModelL Series
CategoryEngine
LanguageEnglish

Related product manuals