Input/output setting mode
63 DAD
When the input signal (DAD) is turned ON, the down counter will increment by one.
64 DDC
When the input signal (DDC) is turned ON, the down counter will decrement by one.
[15]-7
(4) Output signal setting table
Serial
No.
Function Specifications
1...16 OT0...OTF
When the input signal (IO0) that outputs to the virtual output 0 is turned ON, the
virtual output signal (OT0) will turn ON at any time.
(Same for OT1 to OTF)
17...24 FN1...FN8
When the pattern data function code 1 data (FNC1) is read in during sewing, the
function code 1 output signal (FN1) will be reversed <<ON/OFF>>
* When function code 1 data (FNC1) is read in at an odd number:
[The function code 1 output signal (FN1) will turn <<ON>>.]
* When function code 1 data (FNC1) is read in at an even number:
[The function code 1 output signal (FN1) will turn <<OFF>>.]
(Same for FN2 to FN8)
25...32 OF1...OF8
When the work holder input signal 1 (IF1) is turned ON, the work holder output
signal 1 (OF1) will turn ON. When the work holder input signal 1 (IF1) is turned ON,
the work holder output signal 1 (OF1) will turn OFF.
(Same for OF2 to OF8)
33 NO
Nothing is output.
34 T
The thread trimming output signal will turn [ON/OFF].
35 L
The thread release output signal will turn [ON/OFF].
36 W
The wiper output signal will turn [ON/OFF].
37 PF
The presser bar lifting output signal will turn [ON/OFF].
38 AFL
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[first time], the pneumatic type two stage work holder low pressure output (AFL) will
turn ON. Note that this is valid when the [pneumatic type two stage work holder
setting (AF2)] in the [G] mode is set to [ON].
39 AFH
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[second time], the pneumatic type two stage work holder high pressure output
(AFH) will turn ON. Note that this is valid when the [pneumatic type two stage work
holder setting (AF2)] in the [G] mode is set to [ON].
40 AFE
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[second time], the pneumatic type two stage work holder excess work holder
release output (AFE) will turn ON. Note that this is valid when the [pneumatic type
two stage work holder setting (AF2)] in the [G] mode is set to [ON].
41 DHP
The home position output signal (DHP) will turn ON when the sewing machine is
stopped at the home position.
[Note that this will turn on at the virtual home position instead of the mechanical
home position when free home position or home position correction is executed.]
42 D2H
The secondary home position output signal (D2H) will turn ON when the sewing
machine is stopped at the secondary home position.
43 RED
If the sewing machine can be driven (the work holder is lowered (ON)), when the
start switch is pressed, the READY output signal (RED) will turn ON.
44 DSW
When the sewing machine is stitching (including feed data), the during stitching
signal (DSW) will turn ON.
45 SP
When the sewing machine starts to rotate after feed data the output signal (SP) will
turn ON.
46 TSE
The thread trimming start output signal (TSE) will turn ON when the thread trimming
operation starts.
47 END
The stitching end output signal (END) will turn ON when one stitching pattern is
completed.
48 DCS
When the sewing machine is halted with the HALT code data (UST, DST) during
stitching, the HALT (code) output signal (DCS) will turn ON.
49 DST
The halted output signal (DST) will turn ON while the sewing machine is halted.
50 HPO
The during home return output signal (HPO) will turn ON while the sewing machine
is returning to the home position.