Troubleshooting
MSA
US
-CRC Corrupt RFID tag. Enter cylinder information via manual setup
screens.
-Identifier
Test Stand (number) If Status is Fail, then:
-IR Cycle power to the Test Stand. Ensure there is no dirt on the gas
detector blocking the IR interface. If the problem persists, return to
an Authorized MSA Service Center for repair.
-Pump chapter 6, under Pump Fault or Flow Fault
-Flow chapter 6, under Pump Fault or Flow Fault
-SD Card 90% Full Replace SD card or delete files.
-SD Card 100% Full Replace SD card or delete files.
-Power Supply 6V If another GX2 power supply is available, try exchanging power
supplies. Otherwise, return to an Authorized MSA Service Center
for repair.
-Power Supply 1.8 Return to an Authorized MSA Service Center for repair
-Data A setting was corrupted and factory defaults have been restored for
all settings. Verify all GX2 settings are correct for your application.
-CRC A setting was corrupted and factory defaults have been restored for
all settings. Verify all GX2 settings are correct for your application.
-Configuration Reset This occurs when a Data or CRC fault is detected. This means that
factory defaults have been restored. If this error returns while
making setting changes, return to an Authorized MSA Service
Center for repair.
-Cylinder Comm Communications between the Test Stand and the Cylinder Holder
is disrupted. Verify Cylinder Holder LED status shows green; push
units together to ensure good connection; if problem persists, return
to an Authorized MSA Service Center for repair.
Cylinder Holder (number) If Status is Fail, then: