Static electricity is generated.
[Check item] [Action]
Is the ground connection correct? Connect the ground correctly.
The carriage is locked and cannot move.
[Check item] [Action]
Is the carriage bearing or roller damaged? Replace the carriage.
Is the carriage belt too tight? Adjust the belt tension.
Is the carriage belt loose since some screws are not tight? Tighten the screws.
The keyboard does not work.
[Check item] [Action]
Is the connection between keyboard and mainboard bad? Re-plug or replace the keyboard.
Is there dust or mist on the keyboard surface? Replace the keyboard set.
Abnormal noise occurs during standby mode.
[Check item] [Action]
Are there any loose screws? Tighten the screws firmly.
Is X or Y motor belt tension correct? Adjust the belt tension.
Is the carriage belt tension correct? Adjust the belt tension
Is the driver damaged? Replace the main board.
Abnormal noise occurs from the drum during operation.
[Check item] [Action]
Is X or Y motor belt loose? Adjust the belt tension.
Is the driver damaged? Replace the main board.
Is the drive gear at the drum tightly mounted on the shaft? Replace it.
Are the screws securing the drum to the shaft loose? Tighten the screws firmly.
Is X or Y motor damaged? Replace the X or Y motor.