Operating from Front panel 47
You can check the temperature of the heater during printing.
You can change the pre heater temperature setting for the current print job.
See the following related sections of Panel Setting Menus:
"**>5: Platen Heater" P. 73
Menu 1: Temperature
[1]
Tap .
[2]
Use or to choose the heater you want to check.
It displays the current heater temperature and heater temperature setting
in square brackets.
Note
Indicated temperature is approximate. The accuracy of the temperature is not guaranteed.
The display of the current temperature blinks all the time even the heater still warms up or has reached the target temperature.
Menu 2: Pre Heater
[1]
Tap .
[2]
Use or to change the value.
Tap (Enter) to confirm the change.
Note
The change made is applied to the current job only and is not saved in the
printer.
To save the change in the user type currently selected, go to “Menu 6:
Backup”.
The message "Warming up" appears while the heater is functioning.
While “Warming Up” is displayed, do not touch the media guide.
You could get burn injuries.
Menu 1
Temperature
Temperature 1
Pre Heater: Off
Temperature 2
Platen Heater: 30ºC [50ºC]
Temperature 3
Dryer: 23ºC [30ºC]
Menu 2
Pre Heater
Pre Heater:
(30 - 50) 30ºC
CAUTION