7197 Service Manual Appendix C: Ordering Paper and Supplies
August 2011
201
Windows Command Line Firmware Update Utility
The Windows Command Line version of the Flash Utility is provided to allow batch mode of
operation in a Windows XP environment. If you issue a call to TseFlash.com with no parameter you
will get the following out put that explains the parameters.
Note: This utility requires the TseFlash.exe to be in the same directory. TseFlash.com is just a shell
that sends the command line options to TseFlash.exe to process.
*** TseFlash.com Ver 3.1 ***
Thank you for using TseFlash Flash Memory Writer command line interface utility!
TseFlash [model] [download type] [COM] [parameter] [file] [check model(opt)] [pr
int(opt)] [status(opt)] [ErrorTimeOut(opt)]
[model]--> Selections for the model:
[7167] [7167-X115] [7167-X035] [7167-50X1/60X1] [7168] [7197]
[7197-5X01/6X01] [7198] [7198-1X41/2X41] [7649-F301] [K8] [740X-K59X]
[734X-F306] [734X-F307/7125] [734X-F308] [734X-F309]
[download type]
--> Selections for the download type:
/m - Download firmware main program.
/i - Download firmware IPL program.
/l - Download firmware IPL LAN program.
/a - Download ANK font or combined ANK & CP932 font
for 7167, 7167-X115, 7167-X035, 7167-50X1/60X1, 7168, 7197, 7198,
740X-K59X, 734X-F306.
/s - Download ASIAN font for 7197, 740X-K59X , 734X-F306,
/rs - Download Receipt ASIAN Font for 7167 & Receipt 2 Byte for 7168, 7198
/ss - Download Slip ASIAN font for 7167 & Slip 2 Byte for 7168
/sb - Download SBCS font for 734X-F307/7125, 734X-F309, 7649-F301, 7198-1X41
/2X41, 7197-5X01/6X01, K8 , 734X-F308
/db - Download DBCS font for 734X-F307/7125, 734X-F309, 7649-F301, 7198-1X41
/2X41, 7197-5X01/6X01 , 734X-F308
[com]
--> Selections for the COM port, CPMI, IBMUSB, HID (Only K8) or LAN:
/COMX Where X is any valid integer within 1-20.
[parameter]
--> Selections for interface parameter (Only for RS232 and Ethernet
interface):
For RS232 Only: Please key in the Baud Rate, Parity and Stop Bit
- Baud Rate Selection: /[115200] | [57600] | [38400] | [19200] | [9600] | [48
00] | [2400] | [1200]
- Parity Selection: /[none] | [even] | [odd]
- Stop Bit Selection: /[1] | [2]
For Ethernet Only: Please key in the IP Address
- IP Address Selection:/[xxx.xxx.xxx.xxx]
- xxx is a number from 0 to 255
For CPMI, IBMUSB and HID is ignore
[file]
--> Selections for the filename:
Any valid binary file with extension *.mfw | *.sfn | *.dfn | *.ipl | *.lan |
*.bin (Only for K8)
[check model(opt)]
--> Selections for the check model (Optional Parameter):
/skip Bypass checking printer model number.
/noskip (default) Check printer model number & exit when there's
a mismatch.
[print(opt)]
--> Selections for the print (Optional Parameter):
/print (default) Print printer configuration form.