EasyManua.ls Logo

NCR 7197 II SERIES - XON;XOFF Protocol; DTR;DSR Protocol

NCR 7197 II SERIES
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7197 Series II Owner’s Manual Chapter 5: Communication
August 2011
34
Char./Line Lines/Receipt Transmit Time: (9600 Baud) Transmit Time: (19.2 K Baud) Print Time
20 20 0.4 Seconds 0.2 Seconds 1.2 Seconds
20 40 0.8 Seconds 0.4 Seconds 2.4 Seconds
44 20 0.88 Seconds 0.44 Seconds 1.2 Seconds
44 40 1.76 Seconds 0.88 Seconds 2.4 Seconds
XON/XOFF Protocol
The XON/XOFF characters coordinate the information transfer between the printer and
the host computer. The printer sends an XON character when it is ready to receive data
and it sends an XOFF character when it cannot accept any more data. The software on the
host computer must monitor the communication link as shown in the following flowchart
in order to send data at the appropriate times.
If XON/XOFF has been selected, the printer also toggles the DTR signal, as described in
the next section, but it does not look at the DSR signal to transmit data.
XON character = Hex 11.
XOFF character = Hex 13.
DTR/DSR Protocol
The DTR signal is used to control data transmission to the printer. It is driven low when
the printer is ready to recieve data and driven high when it cannot accept any more data.
Data is transmitted from the printer after it confirms that the DSR signal is low.