3-4  Chapter 3:  Output 
Wheninserialmode,thescannerscansuntilabarcodehasbeenread
oruntilthedeactivatecommandissent.Inserialmode,thescannercan
alsobesettoturnitselfoffafteraspecifiedtimehaselapsed(seeRead
Time‐Out(SerialTriggerMode),whichfollows).
Read Time-Out (Serial Trigger Mode) 
Usethisselectiontosetatime‐out(inmilliseconds)ofthescanner’s
triggerwhenusingserialcommandstotriggerthescanner.Oncethe
scannerhastimedout,youcanactivatethescannereitherbypressing
thetriggerorusingaserialtriggercommand.AfterscanningtheRead
Time‐Outbar
code,setthetime‐outduration(from0‐300,000
milliseconds)byscanningdigitsontheProgrammingChartattheback
ofthismanual,thenscanningSave.Default=0ms(notime‐out).
 
Scanner Power Time-Out Timer 
Note:  TheScannerPowerTime‐outTimeroptiononlyappliesto
Manual/SerialTrigger.
gChartatthebackofthismanual.Default=3 600seconds(1
hour).
eris
fbeing
charged,thescannerdoesnotgointopowerdownmode.
Whenthereisnoactivitywithinaspecifiedtimeperiod,thescanner
enterslowpowermode.ScantheScannerPowerTime‐Outbarcodeto
changethetimeoutduration(inseconds).Thenscanthedigitvalueof
the
duration(from1‐10,800seconds)andtheSavebarcodesonthe
Programmin
Iftherearenotriggerpullsduringthe“scannerpowertime‐outtimer”
interval,thescannergoesinpowerdownmode.Wheneverthetrigger
is
enabled,the“scannerpowertime‐outtimer”isreset.Ifthescann
placedinthebasecradleandthebatteryisintheprocess o