3-8  Chapter 3:  Output 
Output Sequence Overview 
Require Output Sequence 
Whenturnedoff,thebarcodedataisoutputtothehostasthescanner
decodesit.Whenturnedon,alloutputdata mustconformtoanedited
sequenceorthescannerdoesnottransmittheoutputdatatothehost
device.
Note:  ThisselectionisunavailablewhentheMultipleSymbols
Selectionisturnedon.
Output Sequence Editor 
Thisprogrammingselectionpermitsyoutoprogramthescannerto
outputdata(whenscanningmorethanonesymbol)inwhateverorder
yourapplicationrequires,regardlessoftheorderinwhichthebar
codesarescanned.ReadingtheDefaultSequencesymbolprogramsthe
scannertotheUniversalvalues,shownbelow.Theseare
thedefaults.
Becertainyouwanttodeleteorclearallformatsbeforeyoureadthe
DefaultSequencesymbol.
Note:  TomakeOutputSequenceEditorselections,youneedtoknow
thecodeI.D.,codelength,andcharactermatch(es)yourapplication
requires.UsetheAlphanumericsymbols(SampleSymbols)toreadthese
options.
To Add an Output Sequence 
1.  ScantheEnterSequencesymbol(seeMultipleSymbolsinChapter3).
2.  CodeI.D.
OntheSymbologyChartinAppendixA,findthesymbology to
whichyouwanttoapplytheoutputsequenceformat.Locatethe
Hexadecimalvalueforthatsymbologyandscanthe2digit
hexadecimalvalue
fromtheProgrammingChartatthebackofthis
manual.