Response Must Not Contain
Like the setting above, except text entered here
functions as pass/fail test criteria based on the
absence of the text string on a specified server or
URL. The test passes if the text string is not
found. If the string is found, the test fails with
the return code: "Response contains excluded
text."
Return Code
The Return Code set here functions as pass/fail
test criteria. The default is "OK (HTTP 200)." Tap
the field to select a different Return Code from
the list. If your selected Return Code value
matches the actual return code value, the test
passes, and if CyberScope Air receives a different
return code, the test fails.
Reverse Grading
When Reverse Grading is enabled, a test is
considered successful if it fails and a failure if it
succeeds. The Results Codes section of the
results screen includes the message "Grading
has been reversed".