EasyManuals Logo

NETGEAR GS748T User Manual

NETGEAR GS748T
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #290 background imageLoading...
Page #290 background image
290
GS748T Smart Switch
An MST Region comprises of one or more MSTP Bridges with the same MST Configuration
Identifier, using the same MSTIs, and which have no Bridges attached that cannot receive
and transmit MSTP BPDUs. The MST Configuration Identifier has the following components:
1. Configuration Identifier Format Selector
2. Configuration Name
3. Configuration Revision Level
4. Configuration Digest: 16-byte signature of type HMAC-MD5 created from the MST
Configuration Table (a VLAN ID to MSTID mapping)
As there are Multiple Instances of Spanning Tree, there is a MSTP state maintained on a
per-port, per-instance basis (or on a per port per VLAN basis: as any VLAN can be in one and
only one MSTI or CIST). For example, port A can be forwarding for instance 1 while
discarding for instance 2. The port states have changed since IEEE 802.1D specification.
To support multiple spanning trees, a MSTP bridge has to be configured with an
unambiguous assignment of VLAN IDs (VIDs) to spanning trees. This is achieved by:
1. Ensuring that the allocation of VIDs to FIDs is unambiguous.
2. Ensuring that each FID supported by the Bridge is allocated to exactly one Spanning Tree
Instance.
The combination of VID to FID and then FID to MSTI allocation defines a mapping of VIDs to
spanning tree instances, represented by the MST Configuration Table.
With this allocation we ensure that every VLAN is assigned to one and only one MSTI. The
CIST is also an instance of spanning tree with a MSTID of 0.
An instance may occur that has no VIDs allocated to it, but every VLAN must be allocated to
one of the other instances of spanning tree.
The portion of the active topology of the network that connects any two bridges in the same
MST Region traverses only MST bridges and LANs in that region, and never Bridges of any
kind outside the Region, in other words connectivity within the region is independent of
external connectivity.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GS748T and is the answer not in the manual?

NETGEAR GS748T Specifications

General IconGeneral
Basic switching RJ-45 Ethernet ports quantity48
MAC address table16000 entries
Packet buffer memory1.632 MB
Maximum data transfer rate1 Gbit/s
Latency20 µs
I/O ports48 RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T (Auto Uplink on all ports) 4 SFP slots for fiber Gigabit Ethernet modules
Dimensions (WxDxH)440 x 260 x 43 mm
Power requirements100-240VAC 50/60 Hz
Networking features10BASE-T, 100BASE-TX, 1000BASE-T
Connectivity technologyWired
Full duplexYes
Networking standardsIEEE 802.3x
Minimum system requirementsCategory 5 network cables Network card for each PC Network software (e.g., Windows)
Mean time between failures (MTBF)69930 h
SafetyUL listed (UL 1950)/cUL, IEC950/EN60950
LED indicatorsLink, Power
Power consumption (typical)70 W
Storage temperature (T-T)-10 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight4000 g