18 Unidrive M Regen Design Guide
Issue Number: 4
Table 3-2 400 V drive ratings (380 V to 480 V ±10 %)
* The internal EMC filter and negative DC terminal are not accessible on Unidrive M Frames 9E/T, 10E/T and 11E/T. These power formats are
therefore not suitable for Regen systems. Select 9A/D, 10D or 11D power formats only.
Model
Normal Duty Heavy Duty
Max cont
current
Nominal
power at
400 V
Motor
power at
460 V
Peak
current
Max cont
current
Peak
current
Nominal
power at
400 V
Motor
power at
460 V
AkWhp A A A kWhp
03400078 9.5 4 5.0 11.4 7.8
15.6
35
03400100 12 5.5 7.5 13.5 9.5
16.6
45
04400150 16 7.5 10 20.3 15
28
5.5 10
04400172 24 11 15 26.4 16
28
7.5 10
05400270 30 15 20 33 25
43.7
11 20
05400300 31 15 20 34.1 30
60
15 20
06400350 38 18.5 25 41.8 34
60
15 25
06400420 46 22 30 52.8 40
70
18.5 30
06400470 60 30 40 69.3 46
80.5
22 30
07400660 70 37 60 86.9 66
122.5
30 50
07400770 94 45 60 103.4 70
122.5
37 60
07401000 112 55 75 123.2 96
168
45 75
08401340 155 75 100 170.5 124
217
55 100
08401570 180 90 150 202.4 156
273
75 125
09402000* 200 110 150 243.1 180
315
90 150
09402240* 255 132 200 280.5 200
353.5
110 150
10402700* 300 160 250 352 270
472.5
132 200
10403200* 350 200 300 397.1 300
525
160 250
11403770* 437 225 350 481 377
660
185 300
11404170* 460 250 400 506 415
726.2
200 350
11404640* 460 280 450 506 415
726.2
250 400