Unidrive M Regen Design Guide 97
Issue Number: 4
5.5 Combined Regen input filters (combi filter)
Figure 5-31 Schaffner combi filter dimensions (FS6085-83-35-2 and FS6085-125-35-2)
Table 5-22 Schaffner combi filter dimensions (FS6085-83-35-2 and FS6085-125-35-2)
Combi filters listed in Table 3-23 Combi filter selection on page 39 are equipped with an internal thermal switch to prevent the EMC filter
inductor from overheating. The thermal switch must be configured to open the main supply contactor in the event of a thermal overload.
Schaffner model
number
ABCDEFGHKWY Z
FS6085-83-35-2
530 mm
(20.87 in)
150 mm
(5.91 in)
150 mm
(5.91 in)
200 mm
(7.87 in)
178 mm
(7.01 in)
150 mm
(5.91 in)
132 mm
(5.20 in)
620 mm
(24.41 in)
26 mm
(1.02 in)
190 mm
(7.48 in)
M8
6.5 mm
(0.26 in)
FS6085-125-35-2
7 8
H
M8
Y
View A
G
W
D
K
K
B
B
C
E
A
F
Z
T1 T2
Safety Terminal Block
Flex wire AWG 10
Flex wire 4 mm 0.8 N m
2
Solid wire 6 mm
2
Safety Terminal Block
Flex wire AWG 1/0
Flex wire 50 mm 8.0 N m
2
Solid wire 50 mm
2
VIEW A