Safety
information
Introduction
Product
Information
System
design
Mechanical
Installation
Electrical
Installation
Getting
started
Optimization Parameters
Technical
data
Component
sizing
Diagnostics
UL
Information
Unidrive M Regen Design Guide 273
Issue Number: 4
9.15 Menu 18: Application menu 1
9.16 Menu 19: Application menu 2
9.17 Menu 20: Application menu 3
Parameter Range()Default()Type
18.001
Application Menu 1 Power-down Save
Integer
-32768 to 32767 0 RW Num PS
18.002 to
18.010
Application Menu 1 Read-only Integer -32768 to 32767 RO Num ND NC US
18.011 to
18.030
Application Menu 1 Read-write Integer -32768 to 32767 0 RW Num US
18.031 to
18.050
Application Menu 1 Read-write bit Off (0) or On (1) Off (0) RW Bit US
18.051 to
18.054
Application Menu 1 Power-down Save
long Integer
-2147483648 to 2147483647 0 RW Num PS
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination
Parameter Range() Default()Type
19.001
Application Menu 2 Power-down Save
Integer
-32768 to 32767 0 RW Num PS
19.002 to
19.010
Application Menu 2 Read-only Integer -32768 to 32767 RO Num ND NC US
19.011 to
19.030
Application Menu 2 Read-write Integer -32768 to 32767 0 RW Num US
19.031 to
19.050
Application Menu 2 Read-write bit Off (0) or On (1) Off (0) RW Bit US
19.051 to
19.054
Application Menu 2 Power-down Save
long Integer
-2147483648 to 2147483647 0 RW Num PS
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination
Parameter Range()Default()Type
20.001
to
20.020
Application Menu 3 Read-write Integer -32768 to 32767 0 RW Num
20.021
to
20.040
Application Menu 3 Read-write Long
Integer
-2147483648 to 2147483647 0 RW Num
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination