Safety
information
Introduction
Product
Information
System
design
Mechanical
Installation
Electrical
Installation
Getting
started
Optimization Parameters
Technical
data
Component
sizing
Diagnostics
UL
Information
248 Unidrive M Regen Design Guide
Issue Number: 4
See Drive Name Characters 1-4 (11.079).
Drive Mode (11.084) is used to hold the currently active drive mode.
Security Status (11.085) shows the security that will apply when security is enabled by setting a non-zero value for User Security Code (11.030).
If Menu Access Status (11.086) = 0 then only Menu 0 can be accessed with a keypad. If Menu Access Status (11.086) = 1 then all menus can be
accessed with a keypad.
Keypad Port Serial Address (11.090) defines the node address for the keypad port serial comms interface. Normally the default value of 1 is used,
but this can be changed if required. The keypad attached to the port will sense the address automatically.
See Product Identifier Characters (11.064).
See Product Identifier Characters (11.064).
See Product Identifier Characters (11.064).
11.082 Drive Name Characters 13-16
RW Num PT US
-2147483648 to 2147483647
0
11.084 Drive Mode
RO Txt ND NC PT US
Open-loop (1), RFC-A (2), RFC-S (3), Regen (4)
11.085 Security Status
RO Txt ND NC PT PS
None (0), Read-only (1), Status-only (2),
No Access (3)
Value Text
0 None
1 Read-only
2 Status-only
3 No Access
11.086 Menu Access Status
RO Txt ND NC PT PS
Menu 0 (0), All Menus (1)
11.090 Keypad Port Serial Address
RW Num US
1 to 16
1
11.091 Additional Identifier Characters 1
RO Num ND NC PT
-2147483648 to 2147483647
11.092 Additional Identifier Characters 2
RO Num ND NC PT
-2147483648 to 2147483647
11.093 Additional Identifier Characters 3
RO Num ND NC PT
-2147483648 to 2147483647