User Manual N11
Technical data
Industrial PC
www.noax.comPage 90 of 120 3085-US-2.4
15
Technical data
Caution
Subject to change without notice!
Caution
Built‐in options may affect the technical data of the Industrial PC.
The corresponding changes to the technical data of the IPC can be found in the docu
mentation for the options in question.
15.1 General information for the Industrial PC
15.1.1 Environmental conditions
Air circulation:
Unobstructed circulation of surrounding air / cooling air
must be provided at the rear panel.
Ambient temperature during
operation:
The maximum temperatures specified for the different
device types apply to the basic device configuration with
an average of 20% system load (defined by noax load
profile). Increased system load, additional expansion cards,
options and peripheral devices reduce the maximum
tolerable ambient temperature.
Ambient temperature during
storage and transportation:
-4°F to 140°F (-20°C to +60°C)
(-22°F / -30°C for devices with an extended temperature
range)
Humidity:
5–90% relative humidity, non‐condensing
Altitude during operation:
Max. 6562 feet (2000 m) above sea level
15.1.2 Operating position of the Industrial PC
The Industrial PC may only be operated in positions ranging from 90° upward to nor
mal position (= facing forward) to 90° downward. The display is the point of reference.
Fig. 79: Different operating positions of the IPC housing using the example of an S19 housing