Standard System Configuration
3-26
Part 1056418-07
E 2019 Nordson Corporation
Bank assignments are dependent on the number of banks set in Step 5,
and the physical location of the guns. Possibilities are shown in the
following table and Figure 3-24.
Consoles Purge Kits Banks
1 1 single 1 bank: L1. All guns automatically assigned to
L1.
1 1 dual 2 banks: L1 and L2. Assign guns to banks
depending on location.
2 2 single 2 banks: L1 for guns 132 or L1 for guns
116, R1 for guns 1732.
2 2 dual 4 banks: L1 and L2 for guns 116, R1 and R2
for guns 1732.
For example, if you have two consoles with a dual purge kit in each, then
you can set the number of banks to 4 and split up the guns in the master
console (guns 116) between banks L1 and L2, and the guns in the slave
console (guns 1732) between banks R1 and R2.
If you have one console with a dual kit, then you can choose 2 banks, and
assign some guns to L1 and the rest to L2.
L1
R1
L1
L2
1 Console, 1 Single Purge Kit:
1 Bank
2 Consoles, 2 Single Purge Kits:
2 Banks
L1
1 Console, 1 Dual Purge Kit:
2 Banks
2 Consoles, 2 Dual Purge Kits:
2 Banks
L1
L2
R1
R2
Figure 3-24 Bank Configuration Possibilities