Operating Parameters
B-27
Part 1120277_01
E 2012 Nordson Corporation
Seven-Day Clock (contd)
68 Schedule 3 Exit Standby
Description: Used to set the time that the melter will exit the standby mode
during schedule 3.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hour,Hour:Minute,Minute
Use: Set the time that the applicator will exit the standby mode during
schedule 3.
Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
NOTE: Do not set an exit standby time that is outside of the t ime
period defined by the schedule's heater on and off time. The
melter cannot enter the s tandby mode when the heaters are off.
71 Schedules for Monday
Description: Used to select which schedule(s) should be used on Monday.
Value: 0 – Remain at last clock transition
1 – Use just schedule 1
2 – Use just schedule 2
3 – Use just schedule 3
4–Useschedule1and2
5–Useschedule2and3
6–Useschedule1and3
7–Useschedule1,2,and3
Resolution: 1
Default Value: 0
Format: —
Use: Selects the active schedule(s) for the day.
NOTE: If the 0 schedule option is used, the heaters will not turn
on again until the next scheduled heaters on time arrives.