Operating Parameters
B-26
Part 1120277_01
E 2012 Nordson Corporation
65 Schedule 3 Heaters On
Description: Used to set the time that the clock will turn on the heaters during
schedule 3.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hours, Hour: Minute, Minute
Use: Set the desired time for the heaters to turn on.
Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
66 Schedule 3 Heater s Off
Description: Used to set the time that the clock will turn off the heaters during
schedule 3.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hours, Hour: Minute, Minute
Use: Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
67 Schedule 3 Enter Standby
Description: Used to set the time that the melter will enter the standby mode
during schedule 3.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hour,Hour:Minute,Minute
Use: Set the time that the applicator will enter the standby mode
during schedule 3.
Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
NOTE: Do not set an enter standby time that is outside of the
time period defined by the schedule's heater on and off time.
The melter cannot enter the s tandby mode when the heaters are
off.