EasyManua.ls Logo

NSK MEGATORQUE M-ESB-YSB2020AB300 - Page 331

Default Icon
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
— A-8 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
Appendix 2: How to Check Motor Condition
Check resistance of resolver winding
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
2 Check resistance of resolver winding
Figure A-7: Check with the Cable
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
(Tester)
Resolver cable
Motor cable
Ω/
●●●●●●●
●●●●●●●●
Figure A-8: Check the Motor only
3 6 9
2 5 8
1 4 7
(Tester)
Connector lock
Ω/
36
25
14
Motor with
absolute sensor
Motor with
incremental sensor
Table A-11: Checking points and resistance specification: Motor with absolute position sensor
Cable connector Motor connector Result Acceptable value
INC-A
(8) « (4)
(INC-A) (COM)
(1) « (2)
(INC-A) (COM)
INC-B
(7) « (4)
(INC-B) (COM)
(4) « (2)
(INC-B) (COM)
INC-C
(15) « (4)
(INC-C) (COM)
(7) « (2)
(INC-C) (COM)
1. 3.1 W ±1W
2. Variation between
phases A, B, and C:
Maximum 1.0 W
ABS-A
(6) « (4)
(ABS-A) (COM)
(3) « (2)
(ABS-A) (COM)
ABS-B
(5) « (4)
(ABS-B) (COM)
(6) « (2)
(ABS-B) (COM)
ABS-C
(14) « (4)
(ABS-C) (COM)
(9) « (2)
(ABS-C) (COM)
1. 9.4 W ±2W
2. Variation between
phases A, B, and C:
Maximum 1.0 W
l For special winding or long cable over 4m, please consult with NSK.
Table A-12: Checking points and resistance specification: Motor with incremental position
sensor
Cable connector Motor connector Result Acceptable value
INC-A
(8) « (4)
(INC-A) (COM)
(1) « (4)
(INC-A) (COM)
INC-B
(7) « (4)
(INC-B) (COM)
(2) « (4)
(INC-B) (COM)
INC-C
(15) « (4)
(INC-C) (COM)
(3) « (4)
(INC-C) (COM)
1. 3.1 W ±1W
2. Variation between
phases A, B, and C:
Maximum 1.0W
l For special winding or long cable over 4m, please consult with NSK.

Table of Contents