60
SET TURN PRESSURE ALARM
(for Transmitter 1 only)
Information includes (Fig. 53):
> Graphic TURN
> Set Point OFF or a numeric value, flashing.
> Symbol PSI (or M)
Pressing and releasing the S button momentarily (< 2
seconds) will step through the Set Points from OFF to 1000
to 3000 PSI (70 to 205 BAR) in 250 PSI (5 BAR)
increments.
Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
END PRESSURE ALARM screen with the Set Point flashing.
Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
other SET A screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the SET A
screen.
Depressing and holding the M button for 2 seconds or if no
button is pressed for a period of 2 minutes operation will
revert to the NORM or GAUG SURF MAIN screen.
Fig. 53 - SET TURN
The TURN Pressure
Alarm only applies
to TMT 1.