SET END PRESSURE ALARM
information includes (Fig. 54):
> Graphic END
> Set Point numeric value, flashing.
> Symbol PSI (or M)
Pressing and releasing the S button momentarily (< 2
seconds) will increase the Set Point from 300 to 1500 PSI
(20 to 105 BAR) in 100 PSI (5 BAR) increments.
Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
PO2 ALARM screen with the Set Point flashing.
Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
other SET A screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the SET A
screen.
Depressing and holding the M button for 2 seconds or if no
button is pressed for a period of 2 minutes operation will
revert to the NORM or GAUG SURF MAIN screen.
Fig. 54 - SET END PRESSURE
The END Pressure
Alarm will activate
when Pressure in the
Tank being used at
the time (TMT 1, 2 ,
or 3) decreases to the
Alarm Set Point.