Oki Data CONFIDENTIAL
44871001TH Rev.6
6-20
6. MAINTENANCE MENUS
Unit name display Drive restriction condition Remarks
MAIN MOTOR - -
EXIT MOTOR FWD FaceUp Cover close -
EXIT MOTOR REV FaceUp Cover open -
REGIST CLUTCH MAIN MOTOR driving -
T1 HOP CLUTCH MAIN MOTOR driving -
MPT HOP CLUTCH (*1) MAIN MOTOR driving -
DUP FEED CLUTCH (*2) MAIN MOTOR driving -
T2 HOP CLUTCH TRAY2 MOTOR driving OPTION
T2 REG CLUTCH TRAY2 MOTOR driving OPTION
LV FAN TEST - -
FUSER FAN TEST - -
ID FAN TEST - -
(*1) MB471/491
only.
(*2)
No duplex feed clutch is installed.
Note! The rollers that rotate continuously (each of heat rollers, image drums, and
conveying rollers) run in synchronization with the main motor.
Table 4-4