44871001TH Rev.6
4-44
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.19 MPT Assy, Manual Assy
(1) Remove the Cover Side (L) and Cover Side(R). (Refer to 4.2.1 / 4.2.2)
(2) Remove the Cover Front (Top). (Refer to 4.2.6)
(2) Remove the Cover-Assy-OPE. (Refer to 4.2.8.11 ~ 4.2.8.13)
(3) Remove two screws (Silver)
. Remove the Plate-Front .
(4) Remove two screws (Silver)
. Remove the screw (Black) .
(5) Remove MPT Assy
(for MB451/MB451w/MB471/MB471w/MB491/MB491+/
MB491+LP/ES4191 MFP/MPS4200mb/MPS4700mb) or Manual Assy
(for
MB441/MB461/MB461+LP/ES4161 MFP).
(6) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
In case of MB441/MB461/MB461+LP/
ES4161 MFP
Manual Assy
In case of MB451/MB451w/MB471/MB471w/
MB491/MB491+/MB491+LP/ES4191MFP
MPS4200mb/MPS4700mb
MPT Assy
①
②
③
④
⑤
①
③
③
④
⑤