44871001TH Rev.6
4-48
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.21 Guide Eject Lower Assy
(1) Remove the Scanner unit. (Refer to 4.2.8)
(2) Remove the Cover Assy Rear. (Refer to 4.2.20)
(3) Remove two screws (Silver)
. Remove the Cover-Eject .
(At this moment, Plate-Rear is also removed.)
(4) Remove two screws (Silver : 8mm)
. Remove the Cover-Cassette-Rear Assy
and Guide-Eject-Lower-Assy .
(5) Remove the post
. Remove the Separator-SB-FD .
(6) Remove the Lever-Exit-Sensor
and Spring-Sensor-Exit .
(7) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Install Cover-Cassette-Rear Assy
carefully to avoid the FFC cable from being
caught.
A
A
②
③
⑤
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
④
FFC cable