44871001TH Rev.6
4-43
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
⑮
⑮
⑯
⑱
⑲
㉑
㉑
⑰
⑳
A hole to draw the thin cableA hole to draw the thick cable
Thick cable
le
View A
View A
(13) Remove two screws (Silver) . Remove the Plate-Duct-Assy .
(14) Remove the screw (Silver)
. Remove the Plate-Stacker-Lock .
(15) Remove the screw (Silver)
and screw (Black)
and lift off Fuser-Assy after
disconnecting every cable from it.
(16) Installing is performed by the inverse procedure with removing.
Note!
1. Fuser-Assy
may be really hot, beware of handling.
2. Beware of not to touch the DC motor inattentively (Do not rotate the motor).
3. Install the Fuser-Assy
carefully to avoid cables from being caught.
⑪
⑫
⑬
⑬
⑭
⑫
⑬
⑭
⑪
(Reference)
The situation of the Mainbody
without the Plate Base (PWU).