Oki Data CONFIDENTIAL
44871001TH Rev.6
8-28
8. TROUBLESHOOTING PROCEDURES
No.
Category
PJL Status
Code
Error Warning Description
71 Error - 1
2
3
4
5
Wireless startup failed.
Please see Help for details.
Wireless startup failed.
Restart the device.If the
problem is not resolved,
Check cableconnection
between CU board and
Wireless LAN board.
72 Error - 1
2
3
4
5
Wireless settings are incomplete.
Please see Help for details.
Wireless settings are
incomplete.
Try making the manual
settings or automatic
settings once again.If the
problem is not resolved,
initialize the network
settings, and then try
making the manual
settings or automatic
settings once again.
73 Error - 1
2
3
4
5
Not connected to wireless access
point.
Please see Help for details.
Not connected to wireless
access point.
Check that the wireless
access point power
supply is ON. Check
the wireless access
point settings, and then
try making the manual
settings or automatic
settings.
74 Error 40033 (K) 1
2
3
4
5
Please check Image Drum Unit.
Please see Help for details.
The image drum is not
correctly installed.
Error 343 : K