Functions and Operations
5.18 Delaying Output OFF Timing
5-53
Outputting at set intervals → P.5-49
Holding already output comparative outputs
→ P.5-55
D Use the U [UP] and S [SHIFT] Keys
to set the password “-0169.” Press the
M [MODE] Key to move to the
advanced function setting level.
•“
L f” is displayed on the level/bank
display to indicate the advanced
function setting level.
E Press the M [MODE] Key several times
to change the PV display to “off-d.”
F Press the S [SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
G Use the U [UP] and S [SHIFT] Keys
to change the set value.
H Press the M [MODE] Key to switch to
the next parameter.
• The set value is registered.
I Press the L [LEVEL] Key for at least
1 s to return to the initial setting level.
1 s min.
J Press the L [LEVEL] Key for at least
1 s to return to RUN level.
1 s min.
SU
M
init
Displays “L f.”
off
L f
M
off-d
0
L f
S
off-d
L f
0000
SU
off-d
0050
L f
M
shot
0
L f
L
L 0
L
123. 4
123. 4
Remarks