Functions and Operations
5.1 Setting Calculations
5-9
5.1 Setting Calculations
The K3HB-S can add, subtract, and display two analog inputs, input A and input B.
A
Select to use only input A.
B
Select to use only input B.
K-A
Select to subtract input A from a constant.
K can be set to any value.
This function is useful for applications such as measuring the
height of a workpiece.
A+B
Select to add input A and B values.
A-B
Select to subtract input B from input A.
This function is useful for applications such as measuring steps in
workpieces.
K-(A+B)
Select to subtract input A and B values from a constant.
K can be set to any value.
This function is useful for applications such as measuring the
thickness of a workpiece.
Initial setting level
S
Explanation of Functions Calculation and constant K
K
K-A
A
B
A-B
A
BA
K
K-(A+B)