Section 5 Functions and Operations
5-54
5.19 Holding Measurement Status
Measurement values, maximum values, minimum values, and output
status can be held while the HOLD input is ON.
The measurement value is held when the HOLD input turns ON.
When the HOLD input turns OFF, the measurement value at that
time is restored.
During HOLD input, signals other than RESET input and bank
number selection using bank selection are not accepted.
If the HOLD input turns ON in no measurement status, when a
sensor error has occurred, or when there is an overflow, the status
at that time is held.
Forced-zero is not accepted during HOLD input.
X V S H
HOLD input
Comparative
set vaLue HH/H
Comparative
set value LL/L
Output HH/H
Output LL/L