Functions and Operations
5.11 Adjusting Timing Inputs
5-33
5.11 Adjusting Timing Inputs
TIMING inputs can be delayed by adjusting the ON timing delay and
OFF timing delay.
* The unit for K3HB-X/V/H settings is 100 ms. For example, if 10 is set,
then the delay is 10 x 100 ms = 1 s.
The on-t (ON timing delay) and off-t (OFF timing delay) settings
can be used for the timing hold set values as shown in the following
table.
●: Setting possible, ---: Setting not possible
Input adjustment level
Parameter Set value Meaning of set value
ON timing delay
on-t
0 to 4999 0 to 4,999 ms
(0 to 499.9 s*)
OFF timing delay
off-t
0 to 4999 0 to 4,999 ms
(0 to 499.9 s*)
Timing hold
set value
tmg-h
ON timing
delay
on-t
OFF timing
delay
off-t
Normal nomal --- ---
Sampling hold s-h ● ---
Peak hold p-h ●●
Bottom hold b-h ●●
Peak-to-peak
hold
p-p ●●
X V S H
on-t
L 1
(ON-T)
ON timing delay
OFF timing delay
TIMING signal
TIMING input
off-t
L 1
(OFF-T)
Applicable models:
K3HB-@@@
+
K35-1
K35-2
K35-3
K35-4