Functions and Operations
Section 5 Functions and Operations
5-34
The following example shows K3HB-S settings for an ON timing delay of 20 ms and an OFF timing delay
of 10 ms.
● Timing Hold Set Value Set to Sampling Hold
● Timing Hold Set Value Set to Peak Hold
Parameter Setting Procedure
Explanation of Functions ON timing delay, OFF timing delay
20 ms 20 ms 20 ms
TIMING
RESET
Measurement
value
Power ON
Delay processing invalid due to reset input.
Timing delay time
No measurement No measurement
Measurement
value 1
Measurement value 2
20 ms 20 ms 20 ms
10 ms 10 ms10 ms
TIMING
RESET
Measurement
value
Power ON
Peak value 1
Peak value 2No measurement No measurement
Delay processing invalid
due to reset input.
A Press the L [LEVEL] Key for at least
3 s in RUN level to move to the initial
setting level.
3 s min.
•“L
0
”
is displayed on the level/bank
display to indicate the initial setting
level.
B Press the L [LEVEL] Key again (less
than 1 s) to move to the input
adjustment level.
1 s max.
•“L 1” is displayed on the level/bank
display to indicate the input
adjustment level.
C Press the S [SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
L
Displays “L 0.”
L 0
L
tmg-h
Displays “L 1."
s-h
L 1
S
tmg-h
nomal
L 1