EasyManua.ls Logo

Omron K3HB-H - About Parameters

Omron K3HB-H
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendices
Appendices
A-18
About Parameters
K3HB-X
fre
50
<
M
M
MODE
<
M
in-ta
IN-TA:
Input type A
*1
FRE:
Power frequency
50, 60 Hz
*2
inp.a1
<
M
<
M
dsp.a1
inp.a2
dsp.a2
dp
<
M
<
M
amoV
nomal
0
<
M
out-p
*1 Refer to the measurement
range table on the front
panel.
L p
L
+
LEVEL
M
MODE
L
+
LEVEL
M
MODE
L a
L
LEVEL
cmwt
off
CMWT:
Communications write
OFF, ON
mm.pt
0
bank
0
run.pt
0
set.pt
1
wt.pt
off
<
M
<
M
zr.pt
off
<
M
M
MODE
<
M
<
M
99999
99999
-19999
-19999
<
M
M
MODE
M
MODE
*Displayed only for
Communications Units.
RUN level
Adjustment level
3 s min.
Power ON
Protect level
1 s max.
Always displayed regardless of model or settings.
Displayed only for certain models or settings.
Parameter Display
1 s min.
* Displayed when bank
selection (bnk-c) is
set to KEY.
L
LEVEL
L
LEVEL
L
LEVEL
L
LEVEL
L 0
L
LEVEL
1 s min.
3 s min.
Measurement starts
Measurement stops
Initial setting level
1 s max.
1 s min.
1 s max.
DSP.A1:
Scaling display value A1
-19,999 to 99,999
*2 This is not displayed in the factory default state.
Change the setting level protection to "0".
L t
L
LEVEL
L
LEVEL
Linear output level L 5
L f
Communications
setting level
L 6
off
stdby
Displayed for Linear
Output Units only.
u-no
len
sbit
prty
sdwt
20
een
9
.6
1
2
7
<
M
<
M
<
M
<
M
<
M
bps
U-NO:
Communications
Unit No. 0 to 99
PRTY:
Parity
None, even, or odd
BPS: Baud rate
9.6, 19.2, or
38.4 kbps
LEN:
Data length
7 or 8 bits
SBIT:
Stop bits
1 or 2 bits
SDWT:
Send wait time
0 to 99 ms
M
MODE
lset.c
4-20
lset.V
1-5
lset.h
<
M
<
M
LSET.H: Linear
output upper limit
19999 to 99999
lset.l
<
M
LSET.L: Linear
output lower limit
19999 to 99999
M
MODE
hys
pass
1
<
M
<
M
<
M
pass
off
init
off
test
Displayed only for
Communications Units.
LSET.C: Linear
current model
0 to 20 mA,
4 to 20 mA
LSET.V: Linear
voltage model
0 to 5 V, 1 to 5 V,
0 to 10 V
STDBY:
Standby sequence
OFF, ON
Output test level
Advanced function setting level
1 s max.
1 s max.
RUN.PT:
RUN/adjustment protect
0 to 2
SET.PT:
Setting level protect
0 to 2
WT.PT:
Setting change protect
OFF,ON
ZR.PT:
Forced-zero protect
OFF,ON
MM.PT:
MAX/MIN protect
0 to 2
Press the @ [LEVEL] key for at least 1 s from any display (except
for the protect level) to return to the first parameter in the RUN or
initial setting level.
BANK: Bank
0 to 7
Measurement value
Comparative set value HH
-
19999 to 99999
Measurement value
Comparative set value H
-
19999 to 99999
Measurement value
Comparative set value L
-
19999 to 99999
Measurement value
Comparative set value LL
-
19999 to 99999
INP.A1:
Scaling input value A1
-19,999 to 99,999
INP.A2:
Scaling input value A2
-19,999 to 99,999
Password:
0169
INIT: Set value initialization
OFF, ON
CMOV:
Move to calibration level
-19,999 to 99,999
S.ERR: Input error enable
OFF, OVER, S.ERR
S-TMR:
Startup compensation timer
0.0 to 99.9 s
BNK-C: Bank selection
OFF, KEY, EV
HP-F:
Previous average
value comparison
OFF, ON
Z-TRM: Zero-trimming
OFF, ON
T-ZR: Tare zero
OFF, ON
O-STP: Output refresh stop
OFF, OUT, ALL
OUT-N:
Output logic
N-O, N-C
SHOT: Shot output
0 to 1,999 (100 ms)
OFF-D: Output OFF-delay
0 to 1,999 (100 ms)
HYS: Hysteresis
0 to 9,999
PASS: PASS output change
LL, L, PASS, H, HH, ERR
TEST: Test input
-19,999 to 99,999
DSP.A2:
Scaling display value A2
-19,999 to 99,999
DP: Decimal point position
0 to 4
OUT-P:
Comparative output pattern
Standard output,
zone output,level output
AMOV:
Move to advanced
function
setting level
-19,999 to 99,999

Table of Contents