Functions and Operations
Section 5 Functions and Operations
5-2
Knowledge Required for Setting Parameters
■ About Levels
Levels are groups of parameters.
Levels for the K3HB are classified as follows:
Important
Depending on the level,
measurements may continue
to be executed or stop.
Check the measurement
operation.
Level Function
Measurement
operations
Protect
Makes settings to prevent
inadvertent key operations.
Movement between levels and
changes to settings may be
prohibited, depending on the protect
settings.
Executed
RUN
The normal operation mode where
inputs are read and comparative
judgements are made.
In RUN level, the present value can
be displayed, comparative set values
checked, and forced-zero executed
or cleared.
The K3HB is in RUN mode
immediately after the power is
turned ON.
Adjustment
Switches banks and makes settings,
such as communications write
settings.
Initial setting
Makes initial settings, such as the
input type, scaling, and comparative
output patterns.
Stopped
Input
adjustment
Adjusts inputs.
Display
adjustment
Enables/disables comparative set
value displays, and sets the display
refresh periods, display color, and
position meter.
Comparative set
value
Makes comparative set value bank
settings.
Linear output
Sets the linear output.
Communications
setting
Sets the baud rate, data length, and
other communications settings.
Output test
Sets test measurement values to
perform output tests.
Advanced
function
settings
Used for advanced customization.