Appendices
Appendices
A-16
*1 Variable C0 is sued for reading communications data.
*2 Set the “bank” parameter to “EV” when an event input (connector) is mounted as a standard feature or
has been added.
Linear
output
Linear current type lset. c 0-20 mA, 4-20 mA 0-20, 4-20 4-20 --- ---
Linear voltage type lset. v 0-5 V, 1-5 V, 0-10 V 0-5, 1-5, 0-10 1-5 --- ---
Linear output upper
limit
lset. h 19999 to 99999 -19999 to 99999 X (VD): 19999
X (AD): 19999
X (VA): 4000
X (AA): 10000
V: 19999
S: 19999
H: 1300. 0
Conforms to decimal
point position.
EU
Linear output lower
limit
lset. l 19999 to 99999 -19999 to 99999 X (VD): -19999
X (AD): -19999
X (VA): 0
X (AA): 0
V: 0
S: -19999
H: -200. 0
Conforms to decimal
point position.
EU
Communi-
cations set-
tings
Communications
protocol
prot CompoWay/F, Modbus cwf, mod cwf --- ---
Communications unit
number
u-no 0 to 99 0 to 99 1 --- ---
Baud rate bps 9.6, 19.2, 38.4 9. 6, 19. 2. 38. 49. 6 --- kbps
Communications data
length
len 7, 8 7, 87--- bit
Communications stop
bits
sbit 1, 2 1, 22--- bit
Communications
parity
prty None, even, odd none, even, odd none --- ---
Send wait time sdwt 0 to 99 0 to 99 20 --- ms
Output test
Test input test OFF, 19999 to 99999 off, -19999 to 99999 off Conforms to decimal
point position.
EU
Advanced
function
settings
Set value initialization init OFF, ON off, on off --- ---
PASS output change pass LL, L, PASS, H, HH,
ERR
ll, l, pass, h, hh, err pass --- ---
Hysteresis hys 0 to 9999 0 to 9999 1 Conforms to decimal
point position.
EU
Output OFF delay off-d 0 to 1999 0 to 1999 0 --- S: ms,
Other
models:
100 ms
Shot output shot 0 to 1999 0 to 1999 0 --- S: ms,
Other
models:
100 ms
Output
logic
out-n Close in alarm, open in
alarm
n-o, n-c n-o --- ---
Output refresh stop o-stp OFF, OUT, ALL off, out, all off --- ---
Tare z e r o t-zr OFF, ON off, on off --- ---
Zero trimming z-trm OFF, ON off, on off --- ---
Previous average
value comparison
hp-f OFF, ON off, on off --- ---
Bank selection bnk-c OFF, KEY, EV off, key, ev off* --- ---
Startup compensation
timer
s-tmr 0.0 to 99.9 0. 0 to 99. 90. 0 1s
Operation at input
error
s.err OFF, overflow, input
error
off, over, s.err s.err --- ---
Standby sequence stdby OFF, ON off, on off
Cold junction
compensation
cjc OFF, ON off, on on
Move to the
calibration level.
cmo? -19999 to 99999 -19999 to 99999 0 --- ---
Others Linear output
calibration value H
--- --- --- --- --- ---
Linear output
calibration value L
--- --- --- --- --- ---
Level Parameter name Characters Setting range Characters Initial value Decimal point Unit Set
value