Appendices
Appendices
A-24
K3HB-H
IN-TA:
Input type A
*1
FRE:
Power frequency
50, 60 Hz
*2
*1 Refer to the measurement range table
on the front panel.
L p
L
+
LEVEL
M
MODE
L
+
LEVEL
M
MODE
L a
L
LEVEL
cmwt
off
CMWT:
Communications write
OFF, ON
bank
0
<
M
<
M
99999
99999
-19999
-19999
<
M
M
MODE
M
MODE
*Displayed only for
Communications Units.
MM.PT:
MAX/MIN protect
0 to 2
RUN level
Adjustment level
3 s min.
Power ON
Protect level
1 s max.
Always displayed regardless of model or settings.
Displayed only for certain models or settings.
Parameter Display
1 s min.
* Displayed when bank
selection (bnk-c) is
set to KEY.
L
LEVEL
L
LEVEL
L
LEVEL
L
LEVEL
L 0
L
LEVEL
1 s min.
3 s min.
Measurement starts
Measurement stops
Initial setting level
1 s max.
1 s min.
1 s max.
*2 This is not displayed in the factory default state.
Change the setting level protection to "0".
L t
L
LEVEL
L
LEVEL
Linear output level L 5
L f
Communications
setting level
L 6
Displayed for Linear
Output Units only.
u-no
len
sbit
prty
sdwt
20
eVen
9
.6
1
2
7
<M
<M
<M
<M
<M
bps
U-NO:
Communications
Unit No. 0 to 99
PRTY:
Parity
None, even, or odd
BPS: Baud rate
9.6, 19.2, or
38.4 kbps
LEN:
Data length
7 or 8 bits
SBIT:
Stop bits
1 or 2 bits
SDWT:
Send wait time
0 to 99 ms
M
MODE
lset.c
4-20
lset.V
1-5
lset.h
<M
<M
LSET.H: Linear
output upper limit
19999 to 99999
lset.l
<M
LSET.L: Linear
output lower limit
19999 to 99999
M
MODE
off
test
Displayed only
for Communi-
cations Units.
LSET.C: Linear
current model
0 to 20 mA,
4 to 20 mA
LSET.V: Linear
voltage model
0 to 5 V, 1 to 5 V,
0 to 10 V
STDBY:
Standby sequence
OFF, ON
Output test level
Advanced function setting level
1 s max.
1 s max.
off
stdby
mm.pt
0
fre
50
<M
M
MODE
<M
in-ta
amoV
nomal
0
<M
out-p
d-u
c
<M
2-k
run.pt
0
set.pt
1
wt.pt
off
<M
<M
<M
M
MODE
1300.0
--200.0
cjc
on
hys
pass
1
<M
<M
pass
off
init
D-U:
Temperature unit
C, F
OUT-P:
Comparative output pattern
Standard output, zone
output, level output
AMOV:
Move to advanced
function setting level
-19999 to 99999
INIT:
Set value initialization
OFF, ON
PASS:
PASS output change
LL, L, PASS, H, HH, ERR
OFF-D:
Output OFF-delay
0 to 1,999 (100 ms)
CMOV:
Move to calibration level
-19,999 to 99,999
S-TMR:
Startup compensation timer
0.0 to 99.9 s
S.ERR:
Input error enable
OFF, OVER, S.ERR
CJC:
Cold junction compensation
OFF, ON
RUN.PT:
RUN/adjustment protect
0 to 2
SET.PT:
Setting level protect
0 to 2
WT.PT:
Setting change protect
OFF,ON
Measurement value
Comparative set value HH
-
19999 to 99999
Measurement value
Comparative set value H
-
19999 to 99999
Measurement value
Comparative set value L
-
19999 to 99999
Measurement value
Comparative set value LL
-
19999 to 99999
BANK: Bank
0 to 7
Press the @ [LEVEL] key for at least 1 s from any display (except
for the protect level) to return to the first parameter in the RUN or
initial setting level.
Password:
0169
HYS: Hysteresis
0 to 9,999
SHOT: Shot output
0 to 1,999 (100 ms)
OUT-N:
Output logic
N-O, N-C
O-STP:
Output refresh stop
OFF, OUT, ALL
HP-F:
Previous average
value comparison
OFF, ON
BNK-C:
Bank selection
OFF, KEY, EV
TEST: Test input
-19,999 to 99,999