Preparations
Section 2 Preparations
2-12
Input type Input range
Maximum
measurement range
Terminal
No.
Input impedance
(A+B)
DC voltage A
±199.99 V −199.99 to 219.99 V E2 10 MΩ min.
B
±19.999 V −19.999 to 21.999 V E3 1 MΩ min.
C
±1.9999 V −1.9999 to 2.1999 V E4
D 1.0000 to 5.0000 V 0.5000 to 5.5000 V E5
DC current A
±199.99 mA −199.99 to 219.99 mA E2 1 Ω max.
B
±19.999 mA −19.999 to 21.999 mA E3 10 Ω max.
C
±1.9999 mA −1.9999 to 2.1999 mA E4 33 Ω max.
D 4.000 to 20.000 mA 2.000 to 22.000 mA E5 10
Ω max.
AC voltage A 0.0 to 400.0 V 0.0 to 440.0 V E1 1 M
Ω min.
B 0.00 to 199.99 V 0.00 to 219.99 V E1
C 0.000 to 19.999 V 0.000 to 21.999 V E3
D 0.0000 to 1.9999 V 0.0000 to 1.9999 V E4
AC current A 0.000 to 10.000 V 0.000 to 11.000 V E2 0.5 VA CT
B 0.0000 to 1.9999 V 0.0000 to 2.1999 V E3
C 0.00 to 199.99 mA 0.00 to 219.99 mA E4 1
Ω max.
D 0.000 to 19.999 mA 0.000 to 21.999 mA E5 10
Ω max.