Preparations
Section 2 Preparations
2-14
K3HB-S:
Analog Input
Input the signal to be measured. The inputs that can be measured by
each model are as follows: Voltage/Current Inputs.
Connect the input devices to the terminals shown below according to
the input type.
Make sure that the absolute maximum rating is not exceeded, even
momentarily.
1
2
3
4
5
6
A
B
C
D
E
-
+
-
+
A
B
AD
AD
V
I
CO
M
120
E4,E5
E3
COM
E3
E1,E
2
E1
E1
E2
E3
E3
E4
E4
E5
E5
E6
E6
N/ C
COM
A
B
A
B
K3HB-S
Input BInput A
4 to 20 mA, 0 to 20 mA
4 to 20 mA, 0 to 20 mA
1 to 5 V, 0 to 5 V
±5 V, ±10 V
1 to 5 V, 0 to 5 V
±5 V, ±10 V
A+B = 1 M