3.6 Panel Thickness Inspection
3-19
Initial Setting Level (L 0)
Input Adjustment Level
(L 1)
Other parameters are set to their default values.
Parameter
Characters
Set value Remarks
Calculation cal 5 K-(A+B)
Input type A in-ta 4-20
Scaling input
value A1
inp.
a14. 000
Scaling display
value A1
dsp. a1 2100
Scaling input
value A2
inp.
a2 20. 000
Scaling display
value A2
dsp. a2 2900
Input type B in-tb 4-20
Scaling input
value B1
inp.
b1 4. 000
Scaling display
value B1
dsp. b1 2100
Scaling input
value B2
inp.
b2 20. 000
Scaling display
value B2
dsp. b2 2900
Constant K k7000Reference panel
thickness 20 mm + sensor
displacement 25 mm
× 2
Decimal point
position
dp ,,,.
,,
-4
4
0
4
20
Displacement
(mm)
Output (mA)
Z4W-V25R
Parameter
Characters
Set value Remarks
Timing hold tmg-h nomal Normal

Table of Contents