Functions and Operations
5.24 Holding maximum and minimum values
5-61
5.24 Holding maximum and minimum values
The maximum and minimum values during measurement can be held.
• The maximum and minimum values are reset when the power is
turned OFF, RESET inputs are received, the [MAX/MIN] Key is
pressed for 1 s, S-TMR inputs are received, and when returning to
RUN level from levels other than adjustment and protect levels.
• Maximum and minimum values are not refreshed when forced-
zero and tare zero are executed or cleared.
● Switching maximum and minimum value displays
Each time the [MAX/MIN] Key is pressed in RUN level, the PV display switches as follows: present
value → maximum value → minimum value → present value.
* If the operation at input error (s.err) is set to s.err and if a sensor error occurs, a.
err or b.
err is held
by the maximum and minimum values.
The error details can be checked using the maximum and minimum value displays. a.
err and b.
err are
cleared by a RESET input or by pressing the [MAX/MIN] Key for 1 s min.
● Resetting maximum and minimum values
Press the [MAX/MIN] Key for 1 s min. in RUN level to reset the maximum and minimum values.
Changing normal display values to maximum and minimum values
→
P.5-62
Max. value
Min. value
Measurement status
Power supply
Initializing Initializing
Measuring
Measuring
Measuring
Measuring
Measurement stopped
90000
Max
1234.5
90000
3012.6
90000
985.7
**
Min
MIN value
MAX value
Present value
Remarks