Appendices
Parameter display conditions
A-11
Parameter display conditions
Level
Protect
Display
Unit
run.pt
set.pt
wt.pt
zr.pt
-
-
-
-
-
bank
cal
in-ta
inp.
a1
dsp.
a1
inp.
a2
dsp.
a2
in-tb
inp.
b1
dsp.
b1
inp.
b2
dsp.
b2
k
dp
out-p
amoV
tmg-h
on-t
off-t
z-lim
lim-p
step
aVg-t
aVg-n
sV.dsp
d.ref
color
disp
ret
pos-t
pos-h
pos-l
sV.bnk
sV .hh
sV .h
sV .l
sV .ll
copy
test
init
pass
hys
off-d
shot
out-n
o-stp
t-zr
z-trm
hp-f
bnk-c
s-tmr
s.err
cmoV
Input
Output
Initialization
RUN
Adjustment
Input
adjustment
Display
adjustment
Comparative
set value
Output test
Advanced-
function setting
Parameter name
RUN/adjustment protect
Setting level protect
Setting change protect
Forced-zero protect
Measurement value
Measurement value/comparative set value HH
Measurement value/comparative set value H
Measurement value/comparative set value L
Measurement value/comparative set value LL
Bank
Calculation
Input type A
Scaling input value A1
Scaling display value A1
Scaling input value A2
Scaling display value A2
Input type B
Scaling input value B1
Scaling display value B1
Scaling input value B2
Scaling display value B2
Constant K
Decimal point position
Comparative output pattern
Move to the advanced-function setting level.
Timing hold
ON timing delay
OFF timing delay
Zero-limit
Zero-limit value
Step value
Average type
Averaging times
Comparative set value display
Display refresh period
Display color selection
Display value selection
Automatic display return
Position meter type
Position meter upper limit
Position meter lower limit
Comparative set value bank
Comparative set value
HH (:0 to 7)
Comparative set value
H (:0 to 7)
Comparative set value
L (:0 to 7)
Comparative set value
LL (:0 to 7)
Bank copy
Test input
Set value initialization
PASS output change
Hysteresis
Output OFF delay
Shot output
Output de-energization
Output refresh stop
Tare zero
Zero-trimming
Previous average comparison
Bank selection
Startup compensation timer
Operation at input error
Move to the calibration level.
<1 to 4>
1
<C1> <C2>
<T1 to 2>
<CPA>
Setting Conditions
PASS output change = PASS or ERR
When the Output Unit is only <CPA>, change in PASS output = HH.
When the Output Unit is only <CPA>, change in PASS output = H.
When the Output Unit is only <CPA>, change in PASS output = L.
When the Output Unit is only <CPA>, change in PASS output = LL.
Bank selection = KEY
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Calculation B
Calculation B
Calculation B
Calculation B
Calculation B
Calculation A or K-A
Calculation A or K-A
Calculation A or K-A
Calculation A or K-A
Calculation A or K-A
Calculation = K-A or K-(A+B)
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Timing hold NormaL
Timing hold Normal or sampling
Zero limit = ON
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Position meter type OFF
Position meter type OFF
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = HH.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = H.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = L.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = LL.
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Timing hold = sampling, peak, or bottom
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
<1 to 4> Event Input
<C1> Relay Output (H/L)
<C2> Relay Output (HH/H/L/LL)
<T1 to 2> Transistor Output
<CPA> PASS Output
Items marked may not be displayed due to Unit configuration or settings. Others are always displayed.
Displayed if the Unit is connected.
Displayed if the Unit is connected and the setting conditions are met.