Functions and Operations
5.31 Performing Output Tests
5-71
5.31 Performing Output Tests
The output test function is used to set a test measurement value using
the keys and to check the comparative output against the set
comparative set value.
The test measurement value is set using the following parameter.
Parameter Setting Procedure
Output test level
Parameter Set value Meaning of set value
Test input
off Output test disabled
-19999 to
99999
-19999 to 99999
A Press the L[LEVEL] Key for at least 3
s in RUN level to move to the initial
setting level.
3 s min.
•"
L
0" is displayed on the level/bank
display to indicate the initial setting
level.
B Press the L[LEVEL] Key several times
to move to the output test level "test".
•"
L
t" is displayed on the level/bank
display to indicate the output test
level.
C Press the S[SHIFT] Key.
The test input will be 0 after moving
to output test status.
D Use the U[UP] and S[SHIFT] Keys to
change the set value.
Use the U[UP] Key to increase the
set value.
Use the S[SHIFT] Key to decrease
the set value.
Continue pressing the key to quickly
increase or decrease the set value.
E Once the output test has finished,
press the L[LEVEL] Key for at least 1
s to return to RUN level.
1 s min.
test
L
t
(TEST)
L
cal
0
Displays "
L
0".
L
0
L
test
off
Displays "
L
t".
L
t
S
test
0
L
t
SU
test
1234
L
t
L
123. 4
123. 4