Basic Application Methods
Basic Application Methods
Section 3 Basic Application Methods
3-8
3.3 Measurement of Disk Eccentricity
Advantages of Using the K3HB-S
The peak-to-peak hold function can be used for simple
eccentricity measurement by measuring the difference between
the maximum and minimum values for linear sensor signals that
change continuously.
Measurements are taken the timing input (the pushbutton switch in
the following diagram) is ON and the last result is held when it is OFF.
Applications such as measuring shaft eccentricity are possible.
(Similar applications are possible for non-metallic objects using an
ultrasonic displacement sensor.)
K3HB-S
Linear Proximity Sensor
E2CA
TIMING input
pushbutton switch
24 VDC
TIMING
Input A
Operating power
supply
Operating power
supply
Connected internally.
COM
COM
+
-
Pushbutton switch
(Measures only while ON.)
12 V
0 V
0 V
Linear output
(+)
Linear Proximity Sensor
E2CA
K3HB-S
+ -