Basic Application Methods
Basic Application Methods
3.3 Measurement of Disk Eccentricity
3-9
K3HB-S Setting Details
Initial setting level (
L
0)
Input adjustment level
(
L
1)
* Only the parameters required for settings are displayed in the initial
setting and input adjustment levels.
Status of workpiece
K3HB-S display (Reset status)
Pushbutton
switch
Linear Proximity
Sensor output
Far
Near
ON
OFF
1 rotation
ON while rotating once or more.
When the workpiece has rotated once or
more, the desired value A is measured.
A
A
Parameter
Characters
Set value Remarks
Calculation cal 0 A
Input type A in-ta 4-20
Scaling input
value A1
inp.
a14.
000
Scaling display
value A1
dsp.
a10.
40
Scaling input
value A2
inp.
a2 20.
000
Scaling display
value A2
dsp.
a2 2.
00
Decimal point
position
dp ,,,.
,,
0.4 2
4
20
Displacement
(mm)
Output (mA)
E2CA
Parameter
Characters
Set value Remarks
Timing hold tmg-h p-p Peak-to-peak hold