Functions and Operations
5.1 Setting Calculations
5-9
5.1 Setting Calculations
The K3HB-S can add, subtract, and display two types of analog inputs, input A and input B.
■ A
• Select to use only input A.
■ B
• Select to use only input B.
■ K-A
• Select to subtract input A from a constant.
• K can be set to any value.
• This function is useful for applications such as measuring the
height of a workpiece.
■ A+B
• Select to add input A and B values.
■ A-B
• Select to subtract input B from input A.
• This function is useful for applications such as measuring steps in
workpieces.
■ K-(A+B)
• Select to subtract input A and B values from a constant.
• K can be set to any value.
• This function is useful for applications such as measuring the
thickness of a workpiece.
Explanation of Functions Calculation and constant K
Initial setting level
K
K-A
A
B
A-B
A
BA
K
K-(A+B)