Functions and Operations
Section 5 Functions and Operations
5-76
Copying bank comparative set values P.5-77
H Use the U[UP] and S[SHIFT] Keys to
change the set value.
I Press the M[MODE] Key to switch to
the next parameter.
The parameter changed in step H is
registered.
J Press the M[MODE] Key several times
to change the PV display to "copy".
K Press the S[SHIFT] Key to make the
SV display flash.
L Use the U[UP] Key to change the set
value.
M Press the M[MODE] Key to switch to
the next parameter "sv.
bnk".
N Press the L[LEVEL] Key for at least 1
s to return to RUN level.
1 s min.
SU
sv1. h
10000
L
4
M
sv1. l
-19999
L
4
Repeat steps F to I to
change other comparative
set values in the same bank.
The settings for all
comparative set values in the
bank have been completed.
Proceed to step
J to copy the
contents of this
bank to all
banks.
Proceed to step
D to set
comparative set
values for other
banks.
Proceed to step N
when bank
comparative set
value settings have
been completed.
M
copy
off
L
4
S
copy
off
L
4
U
on
L
4
copy
M
sv. bnk
0
L
4
Proceed to step D to correct
copied bank parameters.
Proceed to step
N
if bank
comparative set value settings
have been completed.
L
123. 4
123. 4
Remarks