Initialization
4.1 Initialization example
4-3
1. Set the parameter "dp" to ",,.,,," (initial value) and press the M[MODE]
Key.
1. Return to the RUN level by pressing the L[LEVEL] key for at least 1 s.
(Start operation.)
2. Press the M[MODE] key repeatedly until the status display shows ,
and then set the value to "0.
700".
3. Press the M[MODE] key until the status display shows , and then set
the value to "0. 500".
1. Press the M[MODE] key repeatedly to display the measurement values and
start actual operation.
* Refer to Section 5 Functions and Operations for details on making
parameter settings.
E Set the decimal point position.
F Set comparison set value H to 0.700 and set comparison set
value L to 0.500.
G Start actual operation.
H
L
Clearing Settings
If you become confused while setting the parameters and cannot
continue, all settings can be cleared so that you can start over.
Refer to "5.34 Initializing all settings" (P.5-78) for information on
clearing all settings.