Functions and Operations
5.3 Setting Scaling Values
5-13
The decimal point for scaling display values depends on the decimal
point position [dp] setting.
Set constant K [k] when setting the calculation [cal] to K-A[2] or K-
(A+B)[5]
The decimal point will be at the decimal point position.
Scaling is a function that applies sampled input values to a conversion formula that is set beforehand to
convert each input value to a measurement value.
The input value can be converted to Units used by the system.
The scaling conversion formula for voltage/current input is shown below.
Here,
INP1: The input value for measurement value DSP1
DSP1: The measurement value for input value INP1
INP2: The input value for measurement value DSP2
DSP2: The measurement value for input value INP2
inp: Input value for each sampling
dsp: Corresponding measurement value
Parameter Set value Meaning of set value
Decimal point position
dp
,,,,, No decimal point
,,,,., One digit below the decimal
point is displayed.
,,,.,, Two digits below the decimal
point are displayed.
,,.,,, Three digits below the
decimal point are displayed.
,.,,,, Four digits below the decimal
point are displayed.
Parameter Set value Meaning of set value
Constant K
k
-19999 to
99999
-19999 to 99999
Explanation of Functions Scaling
dsp
DSP2 DSP1
INP2 INP1
--------------------------------------- i n p
INP1 DSP2 INP2 DSP1
INP2 INP1
-----------------------------------------------------------------------------+=
inp.1 inp.2
dsp.1
dsp.2
Input value
Display value
inp.1 inp.2
dsp.1
dsp.2
Input value
Display value
Reverse scaling is also possible.
Teaching can be performed using actual inputs.