Functions and Operations
Section 5 Functions and Operations
5-34
Previous average comparison makes the measurement value the difference between the present input
value and the average of all previous input values.
(Vn indicates the input value and Cn indicates the comparative set value used for the next input.)
* Previous average comparison is performed on confirmed measurement values.
• When the timing hold is set to Normal, the comparison is performed every time.
•
When the timing hold is set to a setting other than Normal, the comparison is performed on hold values.
Previous average comparison is set using the following parameter.
Parameter Setting Procedure
Number of
measurements
Input
value
Display
value
Comparative set value for next input
1V
1
V
1
-V
1
=0 C
1
=V
1
2V
2
V
2
-C
1
C
2
=(C
1
+V
2
)= (V
1
+V
2
)
3V
3
V
3
-C
2
C
3
=(C
2
+V
3
)= (V
1
+V
2
)+ V
3
4V
4
V
4
-C
3
C
4
=(C
3
+V
4
)= (V
1
+V
2
)+ V
3
+V
4
·
·
·
·
·
·
·
·
·
·
·
·
nV
n
V
n
-C
n-1
Cn= (V
1
+V
2
)+ V
3
+···+ V
n
1
2
---
1
2
---
1
2
---
1
2
---
1
2
---
1
2
---
1
2
---
1
2
---
1
2
---
1
2
n1–
-------------
1
2
n1–
-------------
1
2
---
Parameter Set value Meaning of set value
Previous average
comparison
hp-f
off Previous average
comparison disabled
on Previous average
comparison enabled
A Press the L[LEVEL] Key for at least 3
s in RUN level to move to the initial
setting level.
3 s min.
•
"
L
0
" is displayed on the level/bank display
to indicate the initial setting level.
B Press the M[MODE] Key several times
to change the PV display to "amov".
•
This parameter is not displayed for the
initial status due to setting level protect.
Refer to "Limiting Key Operations" (P.5-
80) for information on removing setting
level protect.
C Press the S[SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
hp-f
L
f
(HP-F)
L
cal
0
Displays "
L
0".
L
0
M
amov
0
L
0
S
amov
00000
L
0